Sunday, April 18, 2010

Sample questions from "LEED ID&C Exam Guide"

...101. With regard to submittals, what does a project team need to submit for MRc2: Construction Waste Management? (Choose 3)


a. A list of actual materials costs, not including equipment and labor, for materials per CSI MasterFormat™ 2004 Edition Divisions 03-10, 31 (section 31.60.00 Foundations) and 32 (section 32.10.00 Paving, 32.30.00 Site Improvements, and 32.90.00 Planting), including Division 12 is optional

b. A list of actual materials costs, including equipment and labor, for materials per CSI MasterFormat™ 2004 Edition Divisions 03-10, 31 (section 31.60.00 Foundations) and 32 (section 32.10.00 Paving, 32.30.00 Site Improvements, and 32.90.00 Planting), including Division 12 is optional

c. A list of manufacturers' names, product names, costs, and percentage of pre- and post-consumer content

d. Manufacturers' letters or cutsheets indicating the listed products' recycled content

e. A plan showing the location of the recycle area



102. With regard to submittals, what does the project team need to submit for MRc5: Regional Materials? (Choose 3)

a. A list of actual materials costs, not including equipment and labor, for materials per CSI MasterFormat™ 2004 Edition Divisions 03-10, 31 (section 31.60.00 Foundations) and 32 (section 32.10.00 Paving, 32.30.00 Site Improvements, and 32.90.00 Planting), including Division 12 is optional

b. A list of actual materials costs, including equipment and labor, for materials per CSI MasterFormat™ 2004 Edition Divisions 03-10, 31 (section 31.60.00 Foundations) and 32 (section 32.10.00 Paving, 32.30.00 Site Improvements, and 32.90.00 Planting), including Division 12 is optional

c. A list of product purchases extracted, harvested, or manufactured regionally.

d. Paperwork showing manufacturers' names, product names, costs, the distance between the extraction site and the project, and the distance between the manufacturer and the project

e. Manufacturers' letters or cutsheets indicating the materials' origin and manufacture within a 300 miles radius of the site



103. With regard to IEQc5: Indoor Chemical and Pollutant Source Control, which of the following rooms shall be isolated, i.e., the areas are exhausted sufficiently to create a negative pressure when the doors to these areas are closed, provide hard lid ceilings, deck-to-deck partitions, and self-closing doors, etc? (Choose 3)

a. Printing rooms

b. Laundry rooms

c. Gift shops

d. Public restrooms

e. Science laboratories...



You can find more comprehensive study materials, sample questions, mock exam, and information on green building leed certification, and sustainability in LEED ID&C Exam Guide.

No comments:

Post a Comment